Thermostat r and rc jumper - However if you only have wire R wire, you are going to connect it to one of the terminals and put a jumper between them. For Honeywell pro series thermostat thermostats, If there is only one R wire, and it is connected to the R, Rc, or RH terminal, set the slider tap to the up position (1 wire).

 
Hook up the wiring the way you listed it, but leave the jumper between W and Y out. Put the white wire into O on the Ecobee. I've seen these setups many times. leave the jumper out, treat the yellow wire to Y, and the white wire to O/B. report back if its working correctly. The W and Y jumper is there because you do not have auxiliary back up .... Chime money deposit

Jul 28, 2019 ... This video shows how I fixed an error with my Nest thermostat. The error is E74 - No power to Rh wire detected. Learn more at nest.com/e74. R in general. R, Rh, and Rc are all the same, but not. In general terms, the R terminal is where you connect the signal voltage source. In low voltage controlled systems, there will be a step down transformer that provides the power to the control circuitry. One of the legs from the secondary of the transformer will be connected to the R ... If there is an Rc, then it is for Y exclusively. The furnace physically has the blower, so G comes from R. So the 24v comes to R, and out to G for a cooling call's fan. Jumps from R to Rc through a jumper, and then out to Y for the cooling. In this setup, there is only one power source for heating and cooling - thus the jumper.I have the following existing 4 thermostat wires. (GYW) Rc jumper to R With no control wire hidden in the wall. I purchased a 24v outlet adapter to hookup for power but its wires will go to C and Rc.For instance with an older type mercury bulb or snap action thermostat and certain digitals, .. when you place a jumper on terminals with the thermostat in the circuit , the voltage can feed back thru the thermostat to energize unexpected items. I have jumped r to y at a furnace and have the condenser as well as heat come on and vice vera.The c-wire is important because it supplies your thermostat with 24v power. A conventional heating system will typically have 5 wires that you need to wiring as follows: Honeywell rth9585wf wiring diagram definitions: R————the R terminal. C———-the C terminal. G——–G terminal. W——-the W-O/B.Confused about R and RC jumper wire I have a jumper wire on R and Rc. When installing the Nest Thermostat how does this work? Do I just connect the Rc to the nest R and ignore the jumper cable? Locked post. New comments cannot be posted. Share Sort by: Best. Open comment sort options ...No Heat with New Honeywell Thermostat. Thermostat. I just installed a Honeywell T5 thermostat. Since the installation, my heat (electric) has not kicked on (no issues with the old thermostat). I have double checked and reinstalled the wiring as compared to the first thermostat, removed the R to Rc jumper since it’s not needed, and double ...May 4, 2022 · Confirm the message "Cool On" is solid (not blinking) on the thermostat display. Confirm your wiring is correct, and the wires have good contact in the terminals (tug gently on the wires) Check your jumper / R wire. Thermostats get power on the R and Rc terminals.If you have a wire in the R terminal, and no wire in the RC terminal, use the ... We would like to show you a description here but the site won’t allow us.How To Help Series: Honeywell Thermostat R and Rc Terminals with Metal Jumper by 2COR4 - YouTube. Travis Martin. 105 subscribers. Subscribed. 56. 16K views 3 years ago. This video is an...Jumper T18 Replacement Parts; Jumper T16 Replacement Parts; RadioMaster Tx8 Replacement Parts; External Remote Controller Modules; ... trust Grayson Hobby for …If labels do not match letters on the thermostat, check “Alternate Wiring” on page 6 and connect to terminal as shown (see notes, below). We are here to help. Call 1-800-468-1502 for wiring assistance. W/ Aux Not Used M32714 Remove metal jumper if you have both R and Rc wires. M32732 SCREW INSERT WIRES AND TIGHTEN SCREWS WIRE HOLE …The placement of the R wire, also known as the power or 24-volt wire, depends on the specific HVAC system and thermostat setup. In most cases, the R wire is connected to either the RC (cooling) terminal or the RH (heating) terminal on the thermostat. However, there are factors to consider when determining the appropriate connection: 1. Single ...RC and RH are the positive terminal connection ports for 24 volts AC from your thermostat or air handler. There is usually a jumper from RH to RC if you only have one supply of 24 VAC. For two power sources which are quite unusual, the heating appliance will be connected to RH, and the cooling appliances will be connected to RC.Hi. So the old thermostat has a designation of RC and RH, one red wire traveling through both and the new thermostat has two separate slots, one for RH and RC. If so there should be a jumper or you have but a …In the world of remote control (RC) enthusiasts, having reliable and precise control over your models is crucial. That’s where the Futaba FAASTest receiver comes in. One of the sta...Oct 24, 2017 · Since there's only one R wire, you'll need a jumper to get power to both Rc and Rh. If your system has two separate control transformers, you'll have two R wires coming to the thermostat. In this case, you'll remove the jumper and connect the R wires to their respective terminals. Improve this answer. Community Bot. If your old thermostat has more than one label for each connector or you need additional help, visit nest.com/wires Note: The Nest thermostat does not require a jumper wire …remove metal jumper. Connect the R wire to the Rc terminal, and the RH wire to the R terminal. If your old thermostat had only 1 C or C1 wire, connect it to the C terminal. If your old thermostat had 2 C or C1 wires, wrap each separately with electrical tape and do not connect them. Wiring—conventional system Alternate wiring (conventional ...Thermostat. C Wire. Adapter. 1. Turn the power off at the. OFF. breaker box or control. switch for your HVAC* system. ON. OFF. Breaker box. Switch. *Heating, ventilation, and …When testing voltage, seeing ~28V AC from Rc wire, and about ~9V AC from R wire. Currently have a Honeywell ProSeries thermostat. With separate R and Rc you would need the Nest Learning that has Rh and Rc connectors. You need the higher end thermostat and should run a C wire or get the Nest Power Connector kit.Leave metal jumper in place, connecting R & Rc terminals. If your old thermostat had both V and VR wires, stop now and contact a qualified contractor for help. If your old thermostat had separate O and B wires, wrap the B wire in electrical tape and do not connect. If your old thermostat had Y1, W1 and W2 wires, stop now and contact aSince there's only one R wire, you'll need a jumper to get power to both Rc and Rh. If your system has two separate control transformers, you'll have two R wires coming to the thermostat. In this case, you'll remove the jumper and connect the R wires to their respective terminals. Improve this answer. Community Bot.Thermostat. C Wire. Adapter. 1. Turn the power off at the. OFF. breaker box or control. switch for your HVAC* system. ON. OFF. Breaker box. Switch. *Heating, ventilation, and …Dec 30, 2017 ... ... R Quizzes! https ... HVAC TRAINING BOARD: How To Bypass A Thermostat (How To Jump Out A Thermostat) Troubleshooting Tips. Jumper man Tech ... Learning Thermostat Install - R/Rc Jumper. Having some trouble installing my new learning thermostat. I've got an older thermostat with 4 wires, a Y1, G, W1, and R. There is a jumper between the R and Rc terminal. When trying to setup my nest thermostat I've put the R wire into both the Rh and Rc terminals on separate occasions, but in either ... Hi. So the old thermostat has a designation of RC and RH, one red wire traveling through both and the new thermostat has two separate slots, one for RH and RC. If so there should be a jumper or you have but a …Since the installation, my heat (electric) has not kicked on (no issues with the old thermostat). I have double checked and reinstalled the wiring as compared to the first thermostat, removed the R to Rc jumper since it’s not needed, and double/triple checked the breaker. However, I cannot figure out why the heat still does not work. 49. Sort by:Leave metal jumper in place, connecting R & Rc terminals. If your old thermostat had both V and VR wires, stop now and contact a qualified contractor for help. If your old thermostat had separate O and B wires, wrap the B wire in electrical tape and do not connect. If your old thermostat had Y1, W1 and W2 wires, stop now and contact aIn newer thermostat you would normally have the RC or RH terminal. You may have to connect the R wire to any of the two terminals. However may need to put a jumper between the RC and RH terminals with an exception of Nest thermostats which dont require jumping wires. W White Wire. This wire is used to control the heating system.Dec 25, 2021 ... ... Jumper Wires https://amzn.to/3qlN7md Fluke ... HVAC TRAINING BOARD: How To Bypass A Thermostat (How To Jump Out A Thermostat) Troubleshooting Tips.Dec 30, 2017 ... ... R Quizzes! https ... HVAC TRAINING BOARD: How To Bypass A Thermostat (How To Jump Out A Thermostat) Troubleshooting Tips. Jumper man Tech ...Since there's only one R wire, you'll need a jumper to get power to both Rc and Rh. If your system has two separate control transformers, you'll have two R wires coming to the thermostat. In this case, you'll remove the jumper and connect the R wires to their respective terminals. Improve this answer. Community Bot.Bypass the safety switch with one hand and, with one or two other hands, touch a jumper wire (a paperclip will do) between the R/W or R/Y terminals on the control. What probably went wrong. To call for fan the thermostat will short R to G. But you had C on the G terminal, so the thermostat shorted R to C.Answer. Showing 1-7 of 7 answers. Mine old thermostat had a jumper between RC and RH and the wall wire marked R was connected to these. After mounting the new UWP plate to the wall, be sure that the switch selecting either 1 wire or 2 wire is solidly in the correct position. (1 wire position for mine) Mine looked like it was set to 1 wire, but ...When installing a jumper between R and W the R thermostat wire must be removed? The only time this jumper would be removed is if the heating and cooling systems have their own transformer . For instance, if the previous install has a wire going to RH and RC with no jumper then the jumper on Wiser Air should be removed.My old thermostat has G, R, W & Y wires with a jumper between Rc & R. I purchased a Honeywell RTH9585WF Smart Color Thermostat. I moved the G wire to C on the new plate. My furnace has the corresponding wires but there is a black wire in C which was not available at the thermostat plate.Hi. So the old thermostat has a designation of RC and RH, one red wire traveling through both and the new thermostat has two separate slots, one for RH and RC. If so there should be a jumper or you have but a …What is the R-Slider Tab? Last updated. 2/22/22. This is a built-in jumper switch in case there are two transformer systems. If there is only one R-Wire and it is connected to the R, Rc, or Rh terminal on the old thermostat, set the slider to the up position (1 wire). (Slider will automatically hide Rc position and internally jump R and Rc ...The RC terminal supplies the 24-volt cooling power, and the RH terminal is the 24-volt heating power supply. In this article, we’ll look at why most modern thermostats have RC and RH terminals and some (mostly older) thermostats have only one terminal which is marked “R” and how they work.The thermostat you see on your air conditioning unit is wired to a furnace. This furnace houses the heating and cooling systems. Specific wires connect the thermostat and the heater to operate those systems. This is where you’ll see the RH and the RC wires. Usually, these wires are powered with 24 volts. Even though you won’t get any ...Oct 9, 2016 ... ... R Quizzes! https ... Basic Thermostat Wiring - How to Wire HVAC Thermostat ... Jumper man Tech•174K views · 7:22 · Go to ...Radio controlled (RC) airplanes are a fun and exciting hobby that can provide hours of entertainment. Whether you’re a beginner or an experienced flyer, getting started with RC air...We would like to show you a description here but the site won’t allow us.The jumper wire connecting terminals RC and RH are most common, and this jumper wire is not necessary on Sensi thermostat. Sensi thermostats have a built-in RC/RH jumper wire. Below is a table of common jumper connections you may see on your old thermostat base.Apr 18, 2020 ... Common problems with the Nest thermostat, what causes them, and how to fix it. The most common issue with a Nest thermostat not working ...OLD Thermostat: G – G wire, W – W wire, Y – Y Wire, Rc + Rh (R wire with jumper between Rc and Rh) New Thermostat : needs a C wire. Due to old heater panel, I could not find the C wire to hook up. So, hooked up external transformer and connected to C and Rc. Removed jumper between Rc and Rh as suggested by Bill Lee below. Heater works.Set the fan to auto and the system to heat. Then set the thermostat to call for heat by raising the temperature setting. At this point, the red wire will touch the white wire in the thermostat. If the fuse blows at this point, the white wire is shorted and will need to be swapped. In most cases, the heating and cooling system share a single ...Do not jumper any R wires! Rh. If you don’t have an Rc wire, Rh serves as both the heating and cooling power wire. If you only have one R wire (That includes R, Rc, and Rh), you’ll insert it into the Rc terminal on your ecobee. With dual-transformer systems you’ll have two R wires—one from the cooling transformer (Rc) and one from the ...Radio controlled (RC) airplanes are a great way to get into the exciting world of aviation. Whether you’re an experienced pilot or just starting out, RC airplanes offer a wide rang...Does The Red Wire Go To R Or RC On Thermostat?-----James Webb (2022, August 6.) Does the red wire go to R or RC on thermostat? WHYS.videoCopyright 20...Typically, the jumper wire is a small, insulated piece of wire that is strategically positioned to link specific terminals on the thermostat. It serves as a …R in general. R, Rh, and Rc are all the same, but not. In general terms, the R terminal is where you connect the signal voltage source. In low voltage controlled systems, there will be a step down transformer that provides the power to the control circuitry. One of the legs from the secondary of the transformer will be connected to the R ...The R wire controls the heating system, for example, if you have an R and an Rc wire. Is it possible to use RH or RC on my Nest thermostat? The R connector on the Nest Thermostat E is where an R wire would normally go. You can insert the Rc wire into the Rc connector and the Rh wire into the Rh connector because these are not jumper wires.Mar 16, 2021 ... HVAC: How To Check A Thermostat With a Multimeter (Thermostat Troubleshooting) Is It Bad? Explained! Jumper man Tech•50K views · 7:22. If wires are to be connected to both Rc and R, loosen the Rc and R screw terminals and remove the metal jumper wire. 4. If only one of the terminals, Rc or R, is to be connected, leave the metal jumper wire in place. METAL JUMPER WIRE M22295 SCREW TERMINALS TERMINAL BLOCK LETTER DESIGNATIONS R RC Y G C O/B WALLPLATE Before you touch any wires, turn off power to your system from your breaker box. If you still don’t see a C-Wire at your thermostat, check out your HVAC’s control board. There should be a C ...The OLD thermostat had five wires connected to it at the following terminals - Y, R, C, G, and W. See picture below: The instruction manual for the RTH2510 tells me to connect wires to the following terminals - Y, R, G, and W. It doesn't tell me what to do with the remaining C wire. Additionally, there is no C wire terminal on the new ...Previous thermostat has C, G, Y, B, Rc, and then a jumper wire from Rc to Rh. The new thermostat has an R and Rc connection, but nothing to Rh. My uneducated brain assumes I can connect the red wire to R on the new thermostat, throw the jumper wire out, and then everything is gonna be fine, but I don't want to do anything harmful before asking ...Why is there a jumper between R and RC on this thermostat? Effectively there isn’t a second RH wire, although there is an RH terminal. However, the heating still needs to be controlled, so a wire known as a jumper is connected between the RC and the RH terminals so that power gets to the heating control part of the thermostat .When you have two transformers and connect the Rs you get either 0v or 48v at the other connections - it either doubles or cancels out the standard 24vac. Get a multi-meter and measure before hooking up a Nest E. If 48v then need to swap some wires. Easiest done at one of the transformers. Some freak out at this solution as is easy to make a ...Flying remote control (RC) planes is an exhilarating hobby enjoyed by many enthusiasts around the world. Whether you’re a seasoned pilot or just getting started, it’s essential to ...If you’re an aviation enthusiast looking to take your hobby to new heights, Motion RC planes are a fantastic option. With their advanced technology and realistic designs, these rem...Yellow – The yellow wire connects to your compressor. Green – The green wire connects to the fan. Orange – This wire connects to your heat pump (if you have one). Red – Now, there can be two separate wires for this. One is for cool and the other is for heat, hence the abbreviation “RH” and “RC”. Blue – This is your common or ...R and Rc stay jumpered if a jumper came with the thermostat. Use only one R terminal, given that u don't have a two transformer system. if u did, you would have a separate Rc wire. These add a wire kits allow you to put two signals over one wire. Has nothing to do with what was talked about in the video -> Using an external transformer.Bypass the safety switch with one hand and, with one or two other hands, touch a jumper wire (a paperclip will do) between the R/W or R/Y terminals on the control. What probably went wrong. To call for fan the thermostat will short R to G. But you had C on the G terminal, so the thermostat shorted R to C.The R wire controls the heating system, for example, if you have an R and an Rc wire. Is it possible to use RH or RC on my Nest thermostat? The R connector on the Nest Thermostat E is where an R wire would normally go. You can insert the Rc wire into the Rc connector and the Rh wire into the Rh connector because these are not jumper wires.Learning Thermostat Install - R/Rc Jumper. Having some trouble installing my new learning thermostat. I've got an older thermostat with 4 wires, a Y1, G, W1, and R. There is a jumper between the R and Rc terminal. When trying to setup my nest thermostat I've put the R wire into both the Rh and Rc terminals on separate occasions, but in either ...For instance with an older type mercury bulb or snap action thermostat and certain digitals, .. when you place a jumper on terminals with the thermostat in the circuit , the voltage can feed back thru the thermostat to energize unexpected items. I have jumped r to y at a furnace and have the condenser as well as heat come on and vice vera.I just received my Wyze thermostat. I had a simple setup before: it was a standard thermostat that had wires in R (with jumper to Rc), W, Y, G, and C. The Wyze app easily pointed me to Rc, Y1, G, W1, and C. I have pushed the appropriate wires in and plugged the thermostat and put the power back on. The Wyze thermostat does not …The jumper was required with the old stat to energize the compressor on demand for heating or cooling. The new thermostat will energize the compressor for heating or cooling using the Y terminal when you configure it for heat pump operation. Upvote. # 5. 04-14-14, 09:07 PM.Last updated. 2/22/22. The jumper wire can easily be replaced connecting it to the "R" and "RC" terminals on your thermostat wallplate. If you are unable to find the factory installed jumper, a short piece of wire can be used in its place. Please refer to step 1.7 in the Quick Start Guide.No Heat with New Honeywell Thermostat. Thermostat. I just installed a Honeywell T5 thermostat. Since the installation, my heat (electric) has not kicked on (no issues with the old thermostat). I have double checked and reinstalled the wiring as compared to the first thermostat, removed the R to Rc jumper since it’s not needed, and double ...I am installing a new hunter 44668 thermostat, replacing a honeywell th5000. the old wiring had R, Y, C, W, and G. the new one has Y1, RH, RC1, RC, Y/O, W/B, and G. any ideas? … read more Rick MatherThe RC wire, on the other hand, refers to “red cooling”. It’s the same with the RH wire in that it powers the thermostat. For the RC, it powers the cooling system. How Do the RH and the RC Work? The thermostat that you see on your air conditioning unit is wired to a furnace. This furnace houses the heating and the cooling systems.I have Rheem rbhc 24, I want to install a new thermostat, my wires on old thermostat as follows: W- white wire RH- Black jumper wire from RC B- no wire RC-Red wire, with black jumper to RH O- no wire … read moreInsert the jumper loop below the R and Rc terminals if you only have one R or Rc wire. If you have separate R and Rc wires, remove the jumper loop. Connect the wires to the appropriately marked terminals on the wall plate. Attach the thermostat faceplate and turn the power back on. Wiring Details: The thermostat uses 1 wire to control each of ...I hooked the "R" from the furnace and hooked it to the "Rc" on the thermostat base. Nothing on the thermostat. (Hooked up the other way around gave me heat but no AC). So I said my prayers and found the jumper. I jumped "R" and "Rc" on the thermostat base and EVERYTHING WORKS. I have AC, manual over ride on the fan and heat. Rh + Rc with jumper and Nest Thermostat. I just bought a Nest Thermostat (not "Nest Thermostat E", not "Nest Learning Thermostat"). During the installation process, it says that it's not compatible with my system if I select both Rc and Rh. I know that one is for cooling and the other for heating, and I know that the Nest Thermostat has just a ... I hooked the "R" from the furnace and hooked it to the "Rc" on the thermostat base. Nothing on the thermostat. (Hooked up the other way around gave me heat but no AC). So I said my prayers and found the jumper. I jumped "R" and "Rc" on the thermostat base and EVERYTHING WORKS. I have AC, manual over ride on the fan and heat. Answer. Showing 1-7 of 7 answers. Mine old thermostat had a jumper between RC and RH and the wall wire marked R was connected to these. After mounting the new UWP plate to the wall, be sure that the switch selecting either 1 wire or 2 wire is solidly in the correct position. (1 wire position for mine) Mine looked like it was set to 1 wire, but ... Typical would be: red-R (24v power) Yellow-Y (AC stage 1) Green-G (fan) White-W (heat) Blue-C (common) However color doesn't matter as long as the wires used at the furnace control board match at the thermostat terminals. Yes, it is a gas furnace and i don't have a common. i just have green., white, yellow, red and red-c.If you’re an aviation enthusiast looking to take your hobby to new heights, Motion RC planes are a fantastic option. With their advanced technology and realistic designs, these rem...I hooked the "R" from the furnace and hooked it to the "Rc" on the thermostat base. Nothing on the thermostat. (Hooked up the other way around gave me heat but no AC). So I said my prayers and found the jumper. I jumped "R" and "Rc" on the thermostat base and EVERYTHING WORKS. I have AC, manual over ride on the fan and heat.I just received my Wyze thermostat. I had a simple setup before: it was a standard thermostat that had wires in R (with jumper to Rc), W, Y, G, and C. The Wyze app easily pointed me to Rc, Y1, G, W1, and C. I have pushed the appropriate wires in and plugged the thermostat and put the power back on. The Wyze thermostat does not … Very useful but I have a problem. My Honeywell thermostat use only w/g/y/r.-There’s a jumper between w/y and Yellow wire goes on Y.-Green wire goes on G-White wire goes on O-There’s a jumper between Rc and R and Red wire goes on R. No wire goes on B or C. The thermostat is Honeywell TH3110D1008 and I would like to use a Nest Thermostat. However if you only have wire R wire, you are going to connect it to one of the terminals and put a jumper between them. For Honeywell pro series thermostat thermostats, If there is only one R wire, and it is connected to the R, Rc, or RH terminal, set the slider tap to the up position (1 wire).December 13, 2021 at 11:48 PM. Definitive answer: If Rc and Rh (or R) are separate (not shorted with the push up tab) then the common C must come from the AC transformer … Do not jumper any R wires! Rh. If you don’t have an Rc wire, Rh serves as both the heating and cooling power wire. If you only have one R wire (That includes R, Rc, and Rh), you’ll insert it into the Rc terminal on your ecobee. With dual-transformer systems you’ll have two R wires—one from the cooling transformer (Rc) and one from the ...

Received 4,025 Upvotes on 3,611 Posts. You have four wires to your thermostat..... White - W. Green - G. Yellow - Y. Red - R and Rc. You will need more wires to get a C connection to your thermostat. If you use the Ecobee..... it should come with a PEK extender to generate a C connection. Upvote.. Kroger longview tx weekly ad

thermostat r and rc jumper

Does the R wire go to RC or RH? The placement of the R wire, also known as the power or 24-volt wire, depends on the specific HVAC system and thermostat setup. In most cases, …I have the following existing 4 thermostat wires. (GYW) Rc jumper to R With no control wire hidden in the wall. I purchased a 24v outlet adapter to hookup for power but its wires will go to C and Rc.How To Help Series: Honeywell Thermostat R and Rc Terminals with Metal Jumper by 2COR4 - YouTube. Travis Martin. 105 subscribers. Subscribed. 56. 16K views 3 years ago. This … If wires are to be connected to both Rc and R, loosen the Rc and R screw terminals and remove the metal jumper wire. 4. If only one of the terminals, Rc or R, is to be connected, leave the metal jumper wire in place. METAL JUMPER WIRE M22295 SCREW TERMINALS TERMINAL BLOCK LETTER DESIGNATIONS R RC Y G C O/B WALLPLATE I'm upgrading from a White Rodgers thermostat to Honeywell RTH9580WF. The Honeywell requires a C wire. My old White Rodgers thermostat does not have a C connector. It has a wire from the air handler switchboard to the thermostats RC and is has a jumper to RH. (air handler) - (Thermostat) W - W Y - Y G - G R - RC jumper to RHIf you’re an aviation enthusiast looking to take your hobby to new heights, Motion RC planes are a fantastic option. With their advanced technology and realistic designs, these rem...The RC terminal supplies the 24-volt cooling power, and the RH terminal is the 24-volt heating power supply. In this article, we’ll look at why most modern thermostats have RC and RH terminals and some (mostly older) thermostats have only one terminal which is marked “R” and how they work.M&S ladies jumpers are a versatile and stylish addition to any wardrobe. Whether you’re dressing up for a special occasion or keeping it casual for everyday wear, there’s a jumper ... The RC wire, on the other hand, refers to “red cooling”. It’s the same with the RH wire in that it powers the thermostat. For the RC, it powers the cooling system. How Do the RH and the RC Work? The thermostat that you see on your air conditioning unit is wired to a furnace. This furnace houses the heating and the cooling systems. For instance with an older type mercury bulb or snap action thermostat and certain digitals, .. when you place a jumper on terminals with the thermostat in the circuit , the voltage can feed back thru the thermostat to energize unexpected items. I have jumped r to y at a furnace and have the condenser as well as heat come on and vice vera. When you have two transformers and connect the Rs you get either 0v or 48v at the other connections - it either doubles or cancels out the standard 24vac. Get a multi-meter and measure before hooking up a Nest E. If 48v then need to swap some wires. Easiest done at one of the transformers. Some freak out at this solution as is easy to make a ... Thermostat wiring: C low voltage power wire that brings power from heating/cooling equipment to thermostat. RC controls the cooling (at the transformer) has 24V. RH controls the heating (at the transformer) has 24V. G comes from relay that turns on fan. W comes from relay that turns on heating system (at the relay)If your old thermostat had both R and RH wires, remove metal jumper. Connect the R wire to the RC terminal, and the RH wire to the R terminal. Remove metal jumper connecting R and RC only if you must connect both R and RC. Alternate wiring key (conventional system) 2 3 1. 69-2718EF—03 18 If wires are to be connected to both Rc and R, loosen the Rc and R screw terminals and remove the metal jumper wire. 4. If only one of the terminals, Rc or R, is to be connected, leave the metal jumper wire in place. METAL JUMPER WIRE M22295 SCREW TERMINALS TERMINAL BLOCK LETTER DESIGNATIONS R RC Y G C O/B WALLPLATE .