Suction pressure for 410a - Heating mode: outside temp >65F: Run AUX only - lock out compressor (avoid high pressure) outside temp >10F and <65F: Run compressor and AUX as needed. outside temp <10F: Run AUX only - lock out compressor (avoid defrost cycling) Cooling mode: outside temp <60F: lock out compressor, run air handler fan only.

 
Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation.. Tornado warning allen tx

Many servicemen experience service calls where the compressor has both a low head pressure and a high suction pressure. Often, the refrigeration equipment is still running, but the product temperature is suffering about 7 to 10°F. These calls are tough to handle because the compressor is still cooling, but not cooling to its rated capacity.Low-side air conditioner compressor motor pressure: This is the pressure in the air conditioner's refrigerant suction line (low side pressure during compressor operation) and this will be a relatively low number, often less than 100 psi. During operation, refrigerant is returning to the compressor from the cooling (evaporator) coil in this line.The high side guage was connected to the liquid line. Static, both guages are 160 psig. When the unit ran, BOTH guages dropped to about 130. The high side was perhaps 2-5 higher. The amp draw at the compressor was 8.6 RLA out of a 22.1 suggest maximum on the equipment sticker.1. Optimal Cooling. When the low side pressure operates within the recommended range for 410a, your system can efficiently absorb heat from your indoor environment. Any deviation from this range might compromise the cooling efficiency, leaving certain areas less cooled than others. 2.Operating an air conditioner for extended periods of time in low temperatures outdoors lowers the suction pressure to a velocity where the oil will not return to the compressor and will run dry. Also, under low ambient conditions “indoors” does not provide sufficient load to change refrigerant from a liquid to a 100% vapor.Jan 7, 2019 · SUCTION PRESSURE / EVAP DTD RULE OF THUMB Another common old school rule of thumb is suction pressure should be close to the outdoor temperature in a R-22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20˚-25˚ suction saturation below outdoor ambient. (R-508B) is a better replacement than Freon™ 410A. Properties Freon™ 410A is safe to use when proper storage and handling practices are followed. It is a nonflammable, low toxicity mixture of HFC-32 and HFC-125 (50/50 wt%). Freon™ 410A has been classified as A1 by ASHRAE and assigned the ASHRAE number of R-410A. It has beenA R-410A evaporator running below 100 psig will freeze-up just like its R-22 cousin. One of the most common causes of low suction pressure is loss of critical …1. Optimal Cooling. When the low side pressure operates within the recommended range for 410a, your system can efficiently absorb heat from your indoor environment. Any deviation from this range might compromise the cooling efficiency, leaving certain areas less cooled than others. 2.Many women decide to live child-free. Yet, they often feel they owe everyone an explanation about a choice that should be entirely personal. OUR BRANDSpressure relief for R-410A will open at 550-625 psig. Suction and discharged pressure are 40% to 70% greater than R-22 and the discharge temperature of R-410A is lower due to its higher vapor heat capacity. Never heat an R-410A cylinder over 125ºF. • The high-pressure switch will open at 610 psig (plus or minus 10 psig), andThe internal pressure relief valve is located between the high and low side of the compressor. It is designed to open when the discharge-to-suction pressure differential exceeds 550 to 625 psid (38-43 bar). When the valve opens, hot discharge gas is routed back into the area of the motor protector to cause a trip.Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient.R-410A Pressure-temperature chart Click anywhere on this document to return to Refrigerant Gas Properties information at InspectApedia.com This chart was provided by the Bonneville Power Authority,Cleaning services are always in demand and there are many different segments in the industry, here is how to start a pressure washing business. If you buy something through our lin...Here we will learn the R410A Pressure-Temperature Chart. R410A is very commonly used refrigerant that is known as AZ-20”, “Genetron R410A”, “Puron. It is patented by Honeywell. It is mostly used freon in AC systems and works as a replacement for R22. Here we will make an R410A Pressure-Temperature Chart that will help you … The higher pressure, and the fact that R-410A performs very much like a single component refrigerant, provide an opportunity to produce a more compact system with greater efficiency. In addition, R-410A refrigerant allows more suction line pressure drop since it is less sensitive to suction line efficiency losses. View and Download Rheem R-410A installation instructions manual online. PRL-JEC Series two-stage heat pump outdoor units. R-410A heat pump pdf manual download. Also for: Prl-jec series, 024jec, 036jec, 048jec, 060jec. ... Low Suction Pressure Moisture freezing and blocking valve Recover charge, install filter-drier, evacuate system, ...Bedsores (decubitus ulcers) are caused by pressure to areas of skin when resting in a position for too long. Complications can be serious. Learn why. Pressure sores are areas of da...Internal Pressure Relief (IPR) Valve The internal pressure relief valve is located between the high and low side of the compressor. It is designed to open when the discharge-to-suction pressure differential exceeds 550 to 625 psid (38-43 bar). When the valve opens, hot discharge gas is routed back into the area of the motor protector to cause a ...This Guide covers R-22, R-407C, R-410A, and R-134a used in commercial air conditioning systems. It does not apply to industrial refrigeration and/or Variable RefrigerantVolume ... Temperature versus Pressure Drop Refrigerant Suction Pressure Drop Discharge Pressure Drop Liquid Pressure Drop °F (°C) PSI (kPa) °F (°C) PSI (kPa °F (°C) PSI ...HVAC Technician: Mark Henley. Hi, Even with a different refrigerant you are still looking for the same coil temperature. So if you want a 40 degree indoor coil you will be at 120 PSI on the low side, then say you want a 100 degree condensing temperature ( 80 degree day ) you are looking for 320. The desired high side target pressure will change ...liquid and suction lines covering total linear = 200 ft. equivalent lengths up to 240 ft. The philosophy in designing a refrigerant piping system can be summed up as follows: Liquid lines should be sized as small as possible without exceeding the recommended maximum pressure drop of 50 PSI for R-410A. Liquid line pressure My very wild guess would be an obstruction somewhere in the coil or suction line. You eliminated every other cause for a high low pressure (Air flow, refrigerant, compressor txv). I would try touching and observing the piping for any sudden change in temperature. Student here, so take this with a grain of salt. 2. I have a 3Ton Carrier Heat Pump unit using 410A that has extremely high suction pressure around 250PSI. I also have a low liquid line pressure around 300PSI …Weather forecasters can tell what the weather will be by reading the barometric pressure, but how does it work? Advertisement You've probably experienced the scenario where, on a c...These liquid-line restrictions all cause the evaporator, compressor, and condenser to be starved of refrigerant. This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control;R-410A Pressure-temperature chart Click anywhere on this document to return to Refrigerant Gas Properties information at InspectApedia.com This chart was provided by the Bonneville Power Authority,Low suction pressure causes. low suction pressure is developed in the refrigeration system. Some of the most probable causes are as below, The coil is covered with dust or frost. Restriction in the refrigerant line. Filters and strainers are dirty. Faulty fan motor. Low room temperature. Faulty compressor.There's no shortage of cable management options, but often times you need to employ a few different options in order to keep yours neat, tidy, and accessible. When you want to add ...The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.An R-410A Pressure-Temperature (PT) chart is a tool used in HVAC systems to determine the corresponding saturation temperature of the R-410A refrigerant at different pressures. This chart is essential for HVAC technicians as it helps in diagnosing and maintaining air conditioning systems.Both suction and discharge pressure of R-410a systems are _____ than R-22 systems. Lower. Because of its higher vapor capacity, the discharge temperature of R-410a is _____ than R-22. 610 psig plus or minus 10psig. R-410a systems use a high pressure switch that will open at approximately: lose or gain.Mini Split R410a Low Side Suction Charging Service Gauge Hose Set 5/16" Port. 91 Reviews. SKU: PGML-5/16B1/4Y. Free Shipping for Orders Above $49. Wholesale Price Directly From Factory. Secure and Versatile Payment Options. In stock, ready to ship. Price $35 52 $29 99 Save $5.53. Buy in monthly payments with Affirm on orders over $50. Never install suction- line filter drier in the liquid- line of an R-410A system.! CAUTION 7. If suction-line filter drier was installed for system clean up, operate system for 10 hr. Monitor pressure drop across drier. If pressure drop exceeds 3 psig, replace suction-line and liquid-line filter driers. Be sure to purge system with dry nitrogen ... (R-32/125) (50 / 50 wt%) Replaces: R-22. Applications: Air conditioning equipment and heat pumps. Only for newly manufactured equipment, not for retrofitting R-22 systems. …HVAC Technician: Mark Henley. Hi, Even with a different refrigerant you are still looking for the same coil temperature. So if you want a 40 degree indoor coil you will be at 120 PSI on the low side, then say you want a 100 degree condensing temperature ( 80 degree day ) you are looking for 320. The desired high side target pressure will change ...With 410a heat pumps is there a recommended suction pressure. For example with R22 air-con systems I always aim for 400 suction and 1500 discharge and similar with 407c systems. I have been told to aim for round the 100 psi/700kpa mark with is about 0 degree C Was just curious for fault finding purposes. Cheers in advance, chris. liquid and suction lines covering total linear = 200 ft. equivalent lengths up to 240 ft. The philosophy in designing a refrigerant piping system can be summed up as follows: Liquid lines should be sized as small as possible without exceeding the recommended maximum pressure drop of 50 PSI for R-410A. Liquid line pressure R410A systems are much less forgiving, and the only way to get a perfectly charged system is with superheat and subcooling probes. Nonetheless, the low-pressure side should read between 102 and 145 PSI. Anything below this will cause the refrigerant and lines to freeze up. ... Instead, it measures the indoor air handler's suction pressure …In this HVAC Training Video, I show the Step By Step Procedure for Charging R-410A Refrigerant into an Air Conditioner that is Low on Refrigerant. I show the...ESIEN05-04 Disassembly and Maintenance 1.11.1 Removal of Suction Grille Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Procedure: Step Procedure Points 1 Removing the suction grille Push the buttons and pull down Push the 2 buttons When closing, push up the simultaneously and pul...Technical Guide: R-410A Outdoor Split- System Heat Pump - RHP143. York International Corporation, 5005 York Drive, Norman, OK 73069. 2022-10-05 6231804-UTG-A-1022 Supersedes: nothing. 2 Technical Guide: R-410A Outdoor Split-System Heat Pump - RHP143 Johnson Controls Ducted Systems.High Suction Pressure! I have a 3Ton Carrier Heat Pump unit using 410A that has extremely high suction pressure around 250PSI. I also have a low liquid line pressure around 300PSI and my sub-cooling is around 40-50 Degrees. I have checked for a stuck liquid line solenoid but this system does not have one, and I checked the reversing valve and ...Newly released blood pressure suggestions recommend lifestyle changes as a first step toward achieving healthy levels. Trusted Health Information from the National Institutes of He... What should be the 410a suction pressure? As shown in Figure 1 on the next page, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi with R-410A. HFC-32 and HFC-125 are mixed together in R-410A, which is an azeotropic mixture. What is the r410a’s suction and discharge ... The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up just ...An essential tool for charging 410A by subcooling is a set of HVAC gauges. These gauges allow you to measure the pressure in your system, helping you determine the correct refrigerant charge. Make sure to use gauges specifically designed for use with 410A refrigerant.I am a new tech in training and have a problem at my own house. My 410a system keeps freezing up. Filter is new. suction pressure is about 85 which seems low and head pressure is about 230 which seems ok. Super heat goes all over the place from 6 to 16. do you think I have a refrigerant restriction? Any help is greatly appreciated. Thanks.Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation.The upright vacuum cleaner remains the standard, with great suction power. Here are the best upright vacuums from Dyson, Shark and others. By clicking "TRY IT", I agree to receive ...Suction pressure R410A. I ran a system today and had a suction pressure of 5 bar. I have never seen one so low on 410A and charged to manufacturers guidelines, there was frosting on suction valve and inlet/outlets to evap after a couple of minutes. Acson A5LC25CR-ACPOC-R outdoor unit connected to AHU.My very wild guess would be an obstruction somewhere in the coil or suction line. You eliminated every other cause for a high low pressure (Air flow, refrigerant, compressor txv). I would try touching and observing the piping for any sudden change in temperature. Student here, so take this with a grain of salt. 2.Table of Contents. Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, R410A is an HFC and is commonly used in residential and light commercial HVAC equipment for air conditioners and heat pump systems. The R410A PT chart can be used to answer questions like: What are normal operating pressures for 410A? What is the pressure of r410a at 72 degrees Fahrenheit? What should gauge read for 410A? You can also use the R-410A PT chart to adequately calculate the superheat, total superheat, and subcooling temperatures. • supply tee for suction line connection ... to adjust valves when facing adjusting stem clockwise decreases pressure / temperature. counter-clockwise increases pressure / temperature. rawal devices, inc. call tech support: (800) 727-6447 www.rawal.com ©2020 rawal devices, inc. doc#410a-sds.1. Even though this is not the cause of high suction, Clean The Evaporator, because it needs to be clean. If it's dirty, it causes LOW suction pressure, and causes inexperienced techs to overcharge a system. 2. Just for kicks, and for a learning experience, check the system vitals, and record the pressures, water temp entering and leaving the ...R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else.This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.Take the suction pressure and use the pressure/temperature chart to convert it to temperature. Let’s say the suction pressure is 60(Psi) which converts to 34F. And assuming that the suction line temperature is 44F. Then to get superheat we just get the difference between the two temperature readings. In this case, we have 10F of superheat.work on 2 years old r410a heat pump,run in heat mode vapor line pressure 335 psig vapor line temp 80F,liquid line pressure 280psig,ture suction 98 psig,feel like the indoor txv check valve not open enough,switch out new txv,pressure both vapor and liquid only 2 psig different,and vapor line temp go up to 150F,pack u my stuff went home,5 …The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice.what is the benefit of having a fixed orifice over a TXV? 1) they're cheaper and 2) easier to replace. can we have an orifice and a heat pump true or false. true. what is superheat? the amount of heat added to a gas above its saturation point. what is subcool? the heat removed from a liquid below its saturation point. liquid and suction lines covering total linear = 200 ft. equivalent lengths up to 240 ft. The philosophy in designing a refrigerant piping system can be summed up as follows: Liquid lines should be sized as small as possible without exceeding the recommended maximum pressure drop of 50 PSI for R-410A. Liquid line pressure Trying to diagnose a 2 year old Amana heat pump with high suction and discharge pressures in heat mode. ASZ 16 SEER OD unit matched up with an ARUF Goodman piston air handler. Both are 2 ton 410A units. 10kw heat kit and lineset is about 20ft long. HEAT MODE Unit is tripping out on high head(600psi). Upon starting, the unit …Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient.What should my superheat be on a 410a system? For most systems, 20F to 25F should be measured near the compressor and 10F at the evaporator. The system has 10F of superheat if the pressure is 45 psi and the temp is 32F. ... Read and record the suction pressure. Place a digital temperature probe against the suction line near the …suction pressure or too high discharge pressure. They can also be applied to start and stop compressors and the fans of air-cooled ... for high pressure refrigerants (R410A, R744) † Automatic, manual or convertible reset versions available † Vibration and shock resistant AI216886432210en-000901 Data SheetIn this video, I show how a Liquid Line Restriction Affects The Liquid Pressure and Subcooling. I go over the indicators of a Restriction such as vapor satur...Study with Quizlet and memorize flashcards containing terms like Because of its higher vapor heat capacity, the discharge temperature of R-410A is ____ than R-22. A. Higher B. Lower C. The same D. None of the above, R-410A is also known as: A. Suva 410A B. AZ-20 C. Puron D. All the above, Both suction and discharge pressures of R410a systems are …This Guide covers R-22, R-407C, R-410A, and R-134a used in commercial air conditioning systems. It does not apply to industrial refrigeration and/or Variable RefrigerantVolume ... Temperature versus Pressure Drop Refrigerant Suction Pressure Drop Discharge Pressure Drop Liquid Pressure Drop °F (°C) PSI (kPa) °F (°C) PSI (kPa °F (°C) PSI ...liquid and suction lines covering total linear = 200 ft. equivalent lengths up to 240 ft. The philosophy in designing a refrigerant piping system can be summed up as follows: Liquid lines should be sized as small as possible without exceeding the recommended maximum pressure drop of 50 PSI for R-410A. Liquid line pressureThe vapor pressure of R-410A is almost 50% greater than R-22’s vapor pressure. New R-410A systems must be ... In addition, R-410A refrigerant allows more suction line pressure drop since it is less sensitive to suction line efficiency losses. The future of the HVAC & R market looks promising for the development and use of R-410A systems ...Making changes to your diet is a proven way to help control high blood pressure. These changes can also help you lose weight and lower your chance of heart disease and stroke. Maki...Bedsores (decubitus ulcers) are caused by pressure to areas of skin when resting in a position for too long. Complications can be serious. Learn why. Pressure sores are areas of da...AZ-20 (R-410A) pressure is about 60% (1.6 times) greater than R-22. Only use servicing equipment and components designed for AZ-20 (R-410A). – Recovery cylinder service pressure rating 400 psig, e.g. DOT 4BA400 and DOT BW400. – Manifold sets must be 800 psig high-side and 250 psig low-side with 550 psig low-side retard. Refrigerant Type R-410A R-410A R-410A R-410A R-410A R-410A R-410A Refrigerant Charge (limit) lbs 13 13 13 17 17 17 17 Oil Type Trane OIL00079 (qt)/OIL00080 (gal) Oil Charge oz 101 101 101 88 112 112 112 Suction Fitting Connection Brazed Brazed Brazed Brazed Brazed Brazed Brazed Suction Fitting (ODF) in 1.125 1.125 1.125 1.375 1.375 1.375 1.375

The recommended high-pressure control settings are a cut-out pressure of 610 psig and a cut-in pressure of approximately 500 psig. The recommended low …. Carvalho park hilo

suction pressure for 410a

SUBJECT: TEMPERATURE - PRESSURE CHART FOR FYI #289 9/17/2009 R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS ADVANTAGE Engineering, Inc.525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277 web site: www.AdvantageEngineering.com email: [email protected] is a 2-1/2 ton, upflow attic crawlspace. 3/4 x 3/8 copper. Suction pressure fluc 110psi to 130psi. Discharge was 370 on 90+ degree outside temp. went over all connections..all dampers are open..no air leaks drawing from attic. 10 - 12 deg temp difference across coil. Sounds as if you are low on freon.What is the r410a’s standing pressure? When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. What is the best 410a ...R410A PRESSURE-TEMPERATURE CHART Saturation Pressure-Temperature Data for R410A (psig)* ECLPC-1 Rev 1 – 02/22. Created Date: 2/25/2022 1:24:53 PM ...ESIEN05-04 Disassembly and Maintenance 1.11.1 Removal of Suction Grille Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Procedure: Step Procedure Points 1 Removing the suction grille Push the buttons and pull down Push the 2 buttons When closing, push up the simultaneously and pul...The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.They recorded a 245 psi Head pressure and 115 suction pressure on my installation receipt. He also wrote "10 degrees subcool" on the receipt, which I don't see how that is possible when a 245 psi equals 83 degrees on an R-410a P/T chart. The small, copper liquid line (when measured near the compressor valve) doesn't seem to heat up …I have a 3Ton Carrier Heat Pump unit using 410A that has extremely high suction pressure around 250PSI. I also have a low liquid line pressure around 300PSI …What is the r410a’s suction and discharge pressure? R-410A, a new refrigerant that has recently been developed, is currently being used in the HVAC/R industry. As shown in Figure 1 on the next page, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi with R-410A.On the other hand, a 5/8″ suction line on a 3.5 ton is “off the chart,” meaning it isn't acceptable under any conditions. Either way, our goal is to keep suction line pressure drop to a minimum while maintaining the minimum suction velocity, and this is the sweet spot manufacturers keep you in with these charts. #line sizing #suction line.High Suction Pressure R-410a. i went to check an 3.5 ton a/c brand is a ICP (international comfort products) Model WAPL424A1, not cooling my pressures were low side 185 to 190 and high side was around 350 on a 107F hot day. It has a piston as a metering device and compressor was running at 11.50 amps and RLA is 17.25 amps.Suction pressure R410A. I ran a system today and had a suction pressure of 5 bar. I have never seen one so low on 410A and charged to manufacturers guidelines, there was frosting on suction valve and inlet/outlets to evap after a couple of minutes. Acson A5LC25CR-ACPOC-R outdoor unit connected to AHU.what is the benefit of having a fixed orifice over a TXV? 1) they're cheaper and 2) easier to replace. can we have an orifice and a heat pump true or false. true. what is superheat? the amount of heat added to a gas above its saturation point. what is subcool? the heat removed from a liquid below its saturation point.Saturation Pressure-Temperature Data for R410A (psig)*.What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system.Sep 18, 2020 · The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits. So we replace the compressor (same model #), replace the liquid line filter dryer, and evacuate to 500 microns. I weigh the charge in per the manual = unit's orignal charge + addl ounces per foot of lineset - total of 5# 6 oz. Start unit up, damn it, looks wrong immediatelY: Suction: 149.5 psi. Suction Temp: 55.4*F.Saturation Pressure-Temperature Data for R410A (psig)*. Temp (°F) Pressure. Temp (°C)Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both sides, begin from 365 on suction and liquid lines and ….

Popular Topics