Suction pressure for 410a - What is r410a’s suction pressure? When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. Related Articles:

 
R410A Pressure Temperature Chart (In Fahrenheit) Printable PDF Temp er atu r e (° F ): R410A P r essu r e (p si g ):-60 ° F 0. 9 psi g-55 ° F 1. 8 psi g-50 ° F 4. 3 psi g-45 ° F 7. 0 psi g-40 ° F 10. 1 psi g-35 ° F 13. 5 psi g-30 ° F 17. 2 psi g-25 ° F 21. 4 psi g-20 ° F 25. 9 psi g-18 ° F 27. 8 psi g. Sigma chi mit

Nov 16, 2020 · What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system. Let's get started and see what we can do.Most manufacturers recommend charging by super heat and subcoolimg rather than pressures alone,and will vary slightly by manufacturer but as a rule low side of about 110 and high side about 280at 70 degree ambient. This will of course increase as temp warms up.ON an 85 degree day,probably 130 to 135 and ...If the suction pressure is 45 psi, (which converts to 22 ° F) and the suction temp is 32 ° F, the system still has 10 ° F of superheat. The fact that these readings are normal indicates the low suction pressure is not caused by low refrigerant, but insufficient heat getting to the evaporator. CAUSE #2: Defective, plugged, or undersized ...Jul 27, 2012 ... Comments2 ; Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips! AC Service Tech LLC · 1.2M views ; What Should my AC ...And other quick methods to relieve your sinus pressure. Blocked sinuses are no fun—especially during a pandemic, when every single seasonal sniffle or sinus headache results in a n...I have a Lennox 410A heat pump system, model XP19-036-230-01 (2-stage, 3 ton), with indoor unit CBX32MV-036-230-03 and Signature thermostat 81M28. The only problem I can find is a low suction pressure which is 15-20 psi less than normal at design ambient. Other measurements seem OK. Here's an example: Ambient outdoor temp …r-410a pressure temperature chart psig f° psig f° psig f° psig f° psig f° psig f° 12 -37.7 114 37.8 216 74.3 318 100.2 420 120.7 522 137.6 14 -34.7 116 38.7 218 74.9 320 100.7 422 121 524 137.9 16 -32.0 118 39.5 220 75.5 322 101.1 424 121.4 526 138.3Many servicemen experience service calls where the compressor has both a low head pressure and a high suction pressure. Often, the refrigeration equipment is still running, but the product temperature is suffering about 7 to 10°F. These calls are tough to handle because the compressor is still cooling, but not cooling to its rated capacity.The condenser comes charged with 15 feet of 410A. My install has 40 feet of 3/8" and 7/8" line total --- leaving 25 feet needing additional refrigerant. (Goodman suggest adding .6 oz per foot of liquid line) but that seems to be high. At the present time I am setting at 308 (High Side and 143 Low Side with no charge added beyond the 15 foot ...The human heart creates a pressure within the circulatory system every time it beats. Some people experience periods where their blood pressure is too high or too low. When blood M...In this HVAC Training Video, I Show If You Can Check The Refrigerant Charge on an Inverter Mini-Split Ductless Unit on a Service Call by measuring superheat ...Have a 2 ton 410a hp running 75 suction & 365 head pressure od temp is 79 degrees suction line temp is 69 and air coming out the vents is 68 degrees and its 77 degrees in house.. ... should see the suction pressure drop. Then place the bulb in hot water, should see the suction pressure rise. if it does both as I said, its good. How …R410A Pressure Temperature Chart R410A Temperature (°C) Pressure (barA) Pressure (barg) Pressure (psig) Pressure (barA) Pressure (barg) Pressure (psig)-70 0.36 -0.66 -9.52 0.35 -0.66 -9.55-68 0.40 -0.61 -8.85 0.40 -0.61 -8.87-66 0.45 -0.56 -8.10 0.45 -0.56 -8.13-64 0.51 -0.50 -7.27 0.51 -0.50 -7.31-62 0.57 -0.44 -6.37 0.57 -0.44 -6.40This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.After the suction line has been strapped to the joist or rafter at 8’ (2.4 m) intervals, strap the liquid line to the suction line. 8’ (2.4 m) Metal Sleeve Wire Tie (around suction line only) Floor Joist or Roof Rafter Tape or Wire Tie Tape or Wire Tie If hanging line set from a joist or rafter, use metal strapping or heavy nylon wire tiresThe high head probably due to the other guys overcharging, trying to get the suction pressure up. But the low air problem would result in high head pressure in the heat cycle. If the contactor is actually dropping out, I would guess a hi/lo pressure limit opening. Reply . 01-01-2012, 10:14 AM #8.work on 2 years old r410a heat pump,run in heat mode vapor line pressure 335 psig vapor line temp 80F,liquid line pressure 280psig,ture suction 98 psig,feel like the indoor txv check valve not open enough,switch out new txv,pressure both vapor and liquid only 2 psig different,and vapor line temp go up to 150F,pack u my stuff went home,5 …The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice.The internal pressure relief valve is located between the high and low side of the compressor. It is designed to open when the discharge-to-suction pressure differential exceeds 550 to 625 psid (38-43 bar). When the valve opens, hot discharge gas is routed back into the area of the motor protector to cause a trip.Newly released blood pressure suggestions recommend lifestyle changes as a first step toward achieving healthy levels. Trusted Health Information from the National Institutes of He...Sep 28, 2020 ... According to that outdoor temp the pressure will change alot. Your ... R-22 and R-410A Operating Pressures on Air Conditioners! Checking ...What is r410a’s suction pressure? When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. Related Articles:• supply tee for suction line connection ... to adjust valves when facing adjusting stem clockwise decreases pressure / temperature. counter-clockwise increases pressure / temperature. rawal devices, inc. call tech support: (800) 727-6447 www.rawal.com ©2020 rawal devices, inc. doc#410a-sds.No, the same line sizes used for R-22 are used for R-410A. The ideal line size for R-410A is smaller in diameter than R-22 tubing and falls between the standard available nominal refrigerant tubing sizes. The same tubing sizes used for R-22 must be used for R-410A to avoid excessive pressure drops when using the next smaller tube.Refrigerant Properties Freon™ 410A vs. R-22 Discharge Pressure +50 to +70% Cooling Capacity +45% Discharge Temperature –10 °F (-23.3 °C) Energy Efficiency +5 to –5% Lubricant POE. Freon™ 410A Refrigerant For more information on …Study with Quizlet and memorize flashcards containing terms like Because of its higher vapor heat capacity, the discharge temperature of R-410A is _____ than R22, Both suction and discharge pressures of R-410A systems are _____ than R-22 systems, The temperature glide for R-410A is less than _____ degrees Fahrenheit over air …Internal Pressure Relief (IPR) Valve The internal pressure relief valve is located between the high and low side of the compressor. It is designed to open when the discharge-to-suction pressure differential exceeds 550 to 625 psid (38-43 bar). When the valve opens, hot discharge gas is routed back into the area of the motor protector to cause a ...Refrigeration Research, Inc. is pleased to announce new, A.S.M.E. certified suction accumulators intended for use with R410A refrigerant. A.S.M.E. suction accumulators available in standard sizes and volumes, to make your transition to R410A as seamless as possible. All A.S.M.E. suction accumulators are finished with corrosion-resistant powder …Saturation Pressure-Temperature Data for R410A (psig)*. Temp (°F) Pressure. Temp (°C)Mar 26, 2024 · The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load. Many servicemen experience service calls where the compressor has both a low head pressure and a high suction pressure. Often, the refrigeration equipment is still running, but the product temperature is suffering about 7 to 10°F. These calls are tough to handle because the compressor is still cooling, but not cooling to its rated capacity.Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both sides, begin from 365 on suction and liquid lines and …A refrigerator sealed system is a system in which refrigeration occurs. It is composed of the suction tube, metering device evaporator, condenser and compressor. The compressor inc...The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits. Never install suction- line filter drier in the liquid- line of an R-410A system.! CAUTION 7. If suction-line filter drier was installed for system clean up, operate system for 10 hr. Monitor pressure drop across drier. If pressure drop exceeds 3 psig, replace suction-line and liquid-line filter driers. Be sure to purge system with dry nitrogen ... What is r410a’s suction pressure? When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. Related Articles: Filter is new. suction pressure is about 85 which seems low and head pressure is about 230 which seems ok. Super heat goes all over the place from 6 to 16. do you think I have a refrigerant restriction? Any help is greatly appreciated. Thanks. ... My 410a system keeps freezing up. Filter is new. suction pressure is about 85 which …With R-410A, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi, as shown in Figure 1 on the next page.FreonTM 410A. Refrigerant (R-410A) Piping Guide for FreonTM 410A (ENG Units) Technical Information. Suction Line Size—Evaporator to Compressor. 50 °F through 30 … After the suction line has been strapped to the joist or rafter at 8’ (2.4 m) intervals, strap the liquid line to the suction line. 8’ (2.4 m) Metal Sleeve Wire Tie (around suction line only) Floor Joist or Roof Rafter Tape or Wire Tie Tape or Wire Tie If hanging line set from a joist or rafter, use metal strapping or heavy nylon wire tires A bad check valve on an air conditioner, heat pump or similar HVACR equipment can show up as abnormally low or abnormally high suction line pressures, or as abnormally low or high superheat. Experts suggest using an IR heat gun or similar tempeature measuring tool to check the tempeature of the refrigerant line on each side of the valve.Low-side air conditioner compressor motor pressure: This is the pressure in the air conditioner's refrigerant suction line (low side pressure during compressor operation) and this will be a relatively low number, often less than 100 psi. During operation, refrigerant is returning to the compressor from the cooling (evaporator) coil in this line.An essential tool for charging 410A by subcooling is a set of HVAC gauges. These gauges allow you to measure the pressure in your system, helping you determine the correct refrigerant charge. Make sure to use gauges specifically designed for use with 410A refrigerant.Typically, for a properly charged R-410A system, the low-side (suction) pressure may range from 120 to 150 psi, and the high-side (discharge) pressure may range from 300 to 450 psi, depending on factors such as temperature and load. What is the pressure at 100 degrees on 410A?Mini Split R410a Low Side Suction Charging Service Gauge Hose Set 5/16" Port. 91 Reviews. SKU: PGML-5/16B1/4Y. Free Shipping for Orders Above $49. Wholesale Price Directly From Factory. Secure and Versatile Payment Options. In stock, ready to ship. Price $35 52 $29 99 Save $5.53. Buy in monthly payments with Affirm on orders over $50.Operating an air conditioner for extended periods of time in low temperatures outdoors lowers the suction pressure to a velocity where the oil will not return to the compressor and will run dry. Also, under low ambient conditions “indoors” does not provide sufficient load to change refrigerant from a liquid to a 100% vapor.The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.Mini Split R410a Low Side Suction Charging Service Gauge Hose Set 5/16" Port. 91 Reviews. SKU: PGML-5/16B1/4Y. Free Shipping for Orders Above $49. Wholesale Price Directly From Factory. Secure and Versatile Payment Options. In stock, ready to ship. Price $35 52 $29 99 Save $5.53. Buy in monthly payments with Affirm on orders over $50.Mar 26, 2024 · The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load. The condenser comes charged with 15 feet of 410A. My install has 40 feet of 3/8" and 7/8" line total --- leaving 25 feet needing additional refrigerant. (Goodman suggest adding .6 oz per foot of liquid line) but that seems to be high. At the present time I am setting at 308 (High Side and 143 Low Side with no charge added beyond the 15 foot ...So we replace the compressor (same model #), replace the liquid line filter dryer, and evacuate to 500 microns. I weigh the charge in per the manual = unit's orignal charge + addl ounces per foot of lineset - total of 5# 6 oz. Start unit up, damn it, looks wrong immediatelY: Suction: 149.5 psi. Suction Temp: 55.4*F.R-410A system with TXV Readings: Outdoor dB: 95 Outdoor wB: 87 Indoor dB: 82 Indoor wB: 72 Suction Pressure: 164 Suction Temp: 61 Discharge Press: 350 Discharge temp: 96 Supply temperature: 66 So, I've got 11 degrees of Subcooling, which means the charge is about right (based on the chart on the unit), but only 2 degrees of …psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114My very wild guess would be an obstruction somewhere in the coil or suction line. You eliminated every other cause for a high low pressure (Air flow, refrigerant, compressor txv). I would try touching and observing the piping for any sudden change in temperature. Student here, so take this with a grain of salt. 2.Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient. For air conditioning system, R22 pressure in discharge is250psi and suction in67psi. But for R410A pressure will be more higher that R22. So what pressure is normal for air-conditioning systems. Besides that normal R22 compressor can replace with R410A. by Mohammed Awais haji Latif. Get it up to 200 and it would be grossly overcharged. It will be likely running in the 35 to 45f degree saturation (boiling point) range, 108 to 131 psi. The high side has an even greater range. The pressures will vary as the operating conditions like return air temperature, outdoor temperature change.Continue the process until the system has been determined to be leak-free. Connect the vapor-line and liquid-line pressure taps to a vacuum pump and micron meter. This step is also almost always omitted. Evacuate the refrigerant lines and indoor coil to at least 350 microns. Close off the valve to the vacuum pump and observe the micron meter.Theoretical calculations reveal that at the above high-temperature cooling conditions, a 2-psi suction pressure drop produces about 2% loss of efficiency and 2.4% loss of capacity in an R-22 system. But in an R-410A system, the suction pressure drop can be allowed to go as high as 3.1 psi before the same losses in performance are seen.Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient.The high side guage was connected to the liquid line. Static, both guages are 160 psig. When the unit ran, BOTH guages dropped to about 130. The high side was perhaps 2-5 higher. The amp draw at the compressor was 8.6 RLA out of a 22.1 suggest maximum on the equipment sticker.When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. Last updated: 19 days ago – 12 co-authors – 9 users.R410A Systems Run at a Different Pressure. Compared to an R22 system, an R410A air conditioner runs at a higher pressure. These systems operate at about 130 pounds per square inch (psi). ... This will contaminate the system, and the R22 will not evaporate under the higher suction pressure that R410A requires. An HVAC System …With 410a heat pumps is there a recommended suction pressure. For example with R22 air-con systems I always aim for 400 suction and 1500 discharge and similar with 407c systems. I have been told to aim for round the 100 psi/700kpa mark with is about 0 degree C Was just curious for fault finding purposes. Cheers in advance, chris.Mini Split 5/16 in. R410a Low Side Suction Charging Service Gauge Hose Set Port ... Low-side charging manifold with R410A low-side pressure gauge; View More Details; Store 0 in stock. Free & Easy Returns In Store or Online. Return this item within 90 days of purchase. Read Return Policy.liquid and suction lines covering total linear = 200 ft. equivalent lengths up to 240 ft. The philosophy in designing a refrigerant piping system can be summed up as follows: Liquid lines should be sized as small as possible without exceeding the recommended maximum pressure drop of 50 PSI for R-410A. Liquid line pressureTurn the thermostat to cool and set the target temperature at least 10 degrees lower than the indoor temperature. Let the system operate for at least 10 minutes to let pressures equalize. Record the suction line pressure. Use a temperature measuring device to measure the temperature of the suction line.Weather forecasters can tell what the weather will be by reading the barometric pressure, but how does it work? Advertisement You've probably experienced the scenario where, on a c...Operating an air conditioner for extended periods of time in low temperatures outdoors lowers the suction pressure to a velocity where the oil will not return to the compressor and will run dry. Also, under low ambient conditions “indoors” does not provide sufficient load to change refrigerant from a liquid to a 100% vapor.– Freon™ 410A is for new equipment that is specifically designed for R-410A. • Freon™ 410A will require use of manifold gauge sets, recovery machines, and recovery tanks specifically designed for higher pressures encountered with R-410A. Saturation Pressure (psig): R-22 vs. R-410A AC System Considerations (R-508B) is a better replacement than Freon™ 410A. Properties Freon™ 410A is safe to use when proper storage and handling practices are followed. It is a nonflammable, low toxicity mixture of HFC-32 and HFC-125 (50/50 wt%). Freon™ 410A has been classified as A1 by ASHRAE and assigned the ASHRAE number of R-410A. It has been This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.The R410A PT chart can be used to answer questions like: What are normal operating pressures for 410A? What is the pressure of r410a at 72 degrees Fahrenheit? What should gauge read for 410A? You can also use the R-410A PT chart to adequately calculate the superheat, total superheat, and subcooling temperatures.™ 410A Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics of Freon™410A Refrigerant in Very Low Temperature Systems ... Suction Pressure, kPa (psia) 104 (15) 138 (20) Discharge Pressure 1484 (215) 1470 (213) Discharge Temperature 128 (263) 92 (197)The Stonefield Blackhead Extractor is highly regarded as the best blackhead suction vacuum as it can efficiently and effectively extract blackheads, acne and under-skin pimples wit...pressure relief for R-410A will open at 550-625 psig. Suction and discharged pressure are 40% to 70% greater than R-22 and the discharge temperature of R-410A is lower due to its higher vapor heat capacity. Never heat an R-410A cylinder over 125ºF. • The high-pressure switch will open at 610 psig (plus or minus 10 psig), andRefrigerant Properties Freon™ 410A vs. R-22 Discharge Pressure +50 to +70% Cooling Capacity +45% Discharge Temperature –10 °F (-23.3 °C) Energy Efficiency +5 to –5% Lubricant POE. Freon™ 410A Refrigerant For more information on …An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up just ...FreonTM 410A. Refrigerant (R-410A) Piping Guide for FreonTM 410A (ENG Units) Technical Information. Suction Line Size—Evaporator to Compressor. 50 °F through 30 …“For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 … What should be the 410a suction pressure? As shown in Figure 1 on the next page, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi with R-410A. HFC-32 and HFC-125 are mixed together in R-410A, which is an azeotropic mixture. What is the r410a’s suction and discharge ...

Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient.. Is dumpster diving illegal in michigan

suction pressure for 410a

Mar 8, 2010 · Many servicemen experience service calls where the compressor has both a low head pressure and a high suction pressure. Often, the refrigeration equipment is still running, but the product temperature is suffering about 7 to 10°F. These calls are tough to handle because the compressor is still cooling, but not cooling to its rated capacity. Let's get started and see what we can do.Most manufacturers recommend charging by super heat and subcoolimg rather than pressures alone,and will vary slightly by manufacturer but as a rule low side of about 110 and high side about 280at 70 degree ambient. This will of course increase as temp warms up.ON an 85 degree day,probably …410a low suction pressure. I injected super seal in a 410a system that had a tiny leak that I could not find. 2 years later I come across the problem of low suction pressure normal head pressure. Replaced txv and had same problem. Replaced compressor and had the same problem. Could the super seal be clogging the txv or evaporator or condenser ...2. Record the temperature and measure the suction pressure at the suction lines. 3. Convert the suction pressure recorded to the temperature using the temperature/ pressure Chart. 4. To calculate superheat simply subtract the two temperature values. IMPORANT: In most systems. 1. Superheat is about 10 degrees when measured at the evaporator and. 2.Internal Pressure Relief (IPR) Valve The internal pressure relief valve is located between the high and low side of the compressor. It is designed to open when the discharge-to-suction pressure differential exceeds 550 to 625 psid (38-43 bar). When the valve opens, hot discharge gas is routed back into the area of the motor protector to cause a ...Saturation Pressure-Temperature Data for R410A (psig)*. Temp (°F) Pressure. Temp (°C) What should my normal operating pressures on 410a systems be? R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Educate yourself on whats going on in the heat transfer process. ™ 410A Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics of Freon™410A Refrigerant in Very Low Temperature Systems ... Suction Pressure, kPa (psia) 104 (15) 138 (20) Discharge Pressure 1484 (215) 1470 (213) Discharge Temperature 128 (263) 92 (197)High Suction Pressure R-410a. i went to check an 3.5 ton a/c brand is a ICP (international comfort products) Model WAPL424A1, not cooling my pressures were low side 185 to 190 and high side was around 350 on a 107F hot day. It has a piston as a metering device and compressor was running at 11.50 amps and RLA is 17.25 amps.Low suction pressure causes. low suction pressure is developed in the refrigeration system. Some of the most probable causes are as below, The coil is covered with dust or frost. Restriction in the refrigerant line. Filters and strainers are dirty. Faulty fan motor. Low room temperature. Faulty compressor.The internal pressure relief valve is located between the high and low side of the compressor. It is designed to open when the discharge-to-suction pressure differential exceeds 550 to 625 psid (38-43 bar). When the valve opens, hot discharge gas is routed back into the area of the motor protector to cause a trip..